Residential Party Wall Construction Roof Sheathing Ridge
Exterior wall coverings shall be capable of resisting the wind pressures listed in table r301 2 2 wood structural panel sheathing used for exterior walls.
Residential party wall construction roof sheathing ridge. These gypsum products are available in 1 2 inch and 5 8 inch thicknesses and sheet sizes that are 4x8 4x9 and 4x10. Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 10 mm head astm f 1667 of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 mm into the roof sheathing. Structural wall sheathing shall be fastened directly to structural framing members. 201 1 roof sheathing fastening for site built single family residential structures during re roofing.
That structural failures often begin with the roof. And panel sheathing products. Sheathing walls although it is common for sheathing to be included on panelized walls used in residential construction sheathing still takes place on residential construction sites. Fire resistance shall run from foundation to underneath the roof sheathing.
Dwelling units in two family dwellings must be separated from each other by wall and floor assemblies having a minimum 1 hour fire resistance rating. Building inspectors and students in the building trades. Gypsumbased structural sheathing can be paper faced glass mat faced or unfaced core reinforced sheathing. This module also provides for alternate 24 inch spacing of floor wall and roof fram ing where floor and roof trusses are used and accommodates 24 inch spacing of studs where wind loads.
Post disaster evaluations of coastal buildings damaged during high wind events have consistently shown. Where the roof sheathing is less than 3 4 inch 19 mm thick the. Roof and ceiling construction shall be capable of accommodating all loads imposed in accor. The death of the 8 sheet one of the biggest items when sheathing a wall vertically is that the sheathing has to be continuous 602 10 4 5 which meant that an 8 sheet wouldn t cut it in many places so longer ones were required.
So companies like norbord started creating tallwall windstorm panels to help alleviate this. 1510 1 1 roof sheathing shall be fastened to meet the requirements of chapter 16 and 23 of the florida building code building. 2015 seattle residential code 399 chapter 8 roof ceiling construction section r801 general r801 1 application. Components of exterior walls shall be fastened in accor dance with tables r602 3 1 through r602 3 4.
The provisions of this chapter shall control the design and construction of the roof ceiling system for buildings.